{"id":987,"date":"2021-03-09T17:08:54","date_gmt":"2021-03-09T17:08:54","guid":{"rendered":"https:\/\/ewatts-tech.com\/tratamiento-de-aguas\/"},"modified":"2022-03-23T10:43:31","modified_gmt":"2022-03-23T09:43:31","slug":"water-treatment","status":"publish","type":"page","link":"https:\/\/ewatts-tech.com\/en\/water-treatment\/","title":{"rendered":"Water treatments"},"content":{"rendered":"\n<div class=\"wp-block-ewatts-blocks-destacado  mod_destacat var_bg_gris call_to_action_0\"><div class=\"inner maq_marges_horitzontals maq_marges_verticals\"><div class=\"maq_contenidor\"><h2 class=\"com_titular_2 \">ELECTROCHEMICAL (e-T) TREATMENT OF WATER AND AQUEOUS WASTE<\/h2><div class=\"text\"><p>Electrochemical technology relies on the use of electrons for the on-site generation of coagulants or oxidants, using compact and modular equipment that can be set up in reduced spaces and easily extended, if necessary.<\/p><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-desplegable mod_desplegables\"><div class=\"maq_marges_verticals  maq_marges_horitzontals\"><div class=\"maq_contenidor\">\n<div class=\"wp-block-ewatts-blocks-desplegable-in item\"><a class=\"anchor\" id=\"tecnologia-y-capacidades\"><\/a><div class=\"pregunta com_titular_3\"><span class=\"icon-plus\"><\/span><p>Overview of the technology and its capacities<\/p><\/div><div class=\"resposta\">\n<p>Electrochemical technology relies on the use of the electron for the on-site generation of coagulants or oxidants.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrocoagulacion_500px.jpg\" alt=\"\" class=\"wp-image-151\" width=\"300\" height=\"300\" srcset=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrocoagulacion_500px.jpg 500w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrocoagulacion_500px-300x300.jpg 300w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrocoagulacion_500px-150x150.jpg 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"is-style-com_titular_3_blau wp-block-heading\" id=\"e-ect\">Electrocoagulation (e-ECT)<\/h3>\n\n\n\n<p>The technique works by means of an electric field in the space between the cathode and anode (sacrificial anode, which generates the ferric or aluminium hydroxides\/coagulants). <strong>Although the process is similar to the physical-chemical treatment, it offers highly superior performance both in terms of the efficiency of the electro-reduction &#8211; oxidation &#8211; chemical absorption processes and in terms of a substantial reduction in sludge generation (between 30% and 75% less). The process has been successfully used on solids \/ colloids \/ heavy metals \/ hydrocarbon water, oily water, emulsions, or COD \/ TOC \/ easily coagulable total nitrogen.<\/strong><\/p>\n\n\n\n<p>Electrochemical technology reproduces the traditional physical-chemical treatment except that it generates the necessary coagulants on-site without the need to add new salts like aluminium polychloride, ferric chloride, etc.<\/p>\n\n\n\n<p>In addition to acting as a physical-chemical treatment, the electro-chemical reaction results in:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Molecular breakdown reactions (improvement of biodegradation).<\/li><li>Oxidation-reduction reactions.<\/li><li>Chemical and electro-chemical absorption.<\/li><li>Separation and breaking of emulsions \/ oils in the process.<\/li><li>High efficiency in the removal \/ elimination of heavy metals.<\/li><li>Higher suspended solids removal rate with high colloid removal efficiency.<\/li><li>Lower volumes of sludge compared to the physical-chemical process.<\/li><\/ul>\n\n\n\n<p>Reactors with an automated self-cleaning system<\/p>\n\n\n\n<p>Proprietary technology (reactors) under patent.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-clearfloat mod_clearfloat\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrooxidacion_500px.jpg\" alt=\"\" class=\"wp-image-153\" width=\"300\" height=\"300\" srcset=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrooxidacion_500px.jpg 500w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrooxidacion_500px-300x300.jpg 300w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electrooxidacion_500px-150x150.jpg 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"is-style-com_titular_3_blau wp-block-heading\" id=\"e-eot\">Electro-oxidation (e-EOT\/e-EOTph\/e-EDT)<\/h3>\n\n\n\n<p>This process acts through an electric field in the space between anodes and cathodes (long-lasting \/ non-sacrificial), which are made of catalytic noble metals that produce direct anodic oxidation, or indirect oxidation by forming oxidants in the reaction media. This process works far better than high intensity biological treatments (MBR\/SBR\/UASB), chemical oxidative treatments (using pressure\/high temperature oxidation) and\/or mixed treatments. The only difference with high intensity biological treatment is that the EO technique can act on both biodegradable and non-biodegradable molecules.<\/p>\n\n\n\n<p>The electro-oxidation\/<strong>electrodisinfection<\/strong> technique is\u00a0also used for <strong>the\u00a0production of disinfectants to treat, sanitise and disinfect wastewater. <\/strong>The best known technique is the on-site generation of chlorine using sea water or a sodium chloride solution. <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Ref:<\/mark><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\"> e-EOT<\/mark><\/strong><\/p>\n\n\n\n<p>e-Watts has developed a new highly efficient treatment for the oxidation of high organic loads (COD&#8217;s between 5000mg\/L and 50.000mg\/L) either toxic or non-biodegradable (API&#8217;s, emerging pollutants, etc.) for the Chemical-Pharmaceutical and Petrochemical industry that results in an equal or better performance than BDD electrodes but is 10 times cheaper. <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Ref:<\/mark><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\"> e-EOTph<\/mark><\/strong><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<p>Reactors with an automated self-cleaning system.<\/p>\n\n\n\n<p>Proprietary technology (reactors) under patent.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-clearfloat mod_clearfloat\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electroperoxicoagulacion_500px.jpg\" alt=\"\" class=\"wp-image-158\" width=\"300\" height=\"300\" srcset=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electroperoxicoagulacion_500px.jpg 500w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electroperoxicoagulacion_500px-300x300.jpg 300w, https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Img_ewatts_producto_electroperoxicoagulacion_500px-150x150.jpg 150w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"is-style-com_titular_3_blau wp-block-heading\" id=\"e-ept\">Electro-Fenton (EF) with peroxi-coagulation (PC)<\/h3>\n\n\n\n<p>This technique works in the same way as electrocoagulation but adds hydrogen peroxide to generate most of free radicals that guarantee maximum oxidising power. Applicable in wastewater with a high organic or refractory load.<\/p>\n\n\n\n<p>The electrochemical technique of Electro-Fenton <strong>(EF) with peroxi-coagulation (PC)<\/strong>&nbsp;consists of applying an electric field between an iron anode (sacrificial) and a cathode; the water to be treated is passed between this space and generates Fe2+ to act with the hydrogen peroxide, inserted or produced cathodically, causing the Fenton reaction. This process generates a large number of free radicals that act by strongly oxidising any pollutants present in the effluent. Once all the hydrogen peroxide has been absorbed, the residual iron present is removed from the solution, increasing pH levels and separated through physical techniques of decantation, flotation or cross-flow ultrafiltration.<\/p>\n\n\n\n<p><strong><strong>This technique is usually applied to highly refractory, toxic or complex waste, where other techniques have failed to bring about the desired results<\/strong><\/strong> (COD, high organic loads or waste difficult to biodegrade or oxidise by chemical or biological techniques).<\/p>\n\n\n\n<p>Reactors with an automated self-cleaning system.<\/p>\n\n\n\n<p>Proprietary technology (reactors) under patent.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-clearfloat mod_clearfloat\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_3 wp-block-heading\"><strong><strong>Capacities.<\/strong><\/strong>&nbsp;(e-ECT \/ e-EOT\/ e-EDT\/ e-EOTph \/ e-EPT)<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-taula_tamany_1\"><table><thead><tr><th>T\u00e9cnica \/ Reactor<\/th><th>Ref: e-ECT<\/th><th>Ref: e-EO \/ e-EDT \/ e-EOTph<\/th><th>Ref: e-EPT<\/th><\/tr><\/thead><tbody><tr><td><strong>m3 \/ h \/ reactor<br>Model I<br>Model II<\/strong><\/td><td><br>0,5 &#8211; 20<br>5 &#8211; 80<\/td><td><br>0,5-50\/0,5-500\/0,5-50<br>1-150\/1-1.500\/1-150<\/td><td><br>0,5 &#8211; 20<br>5 &#8211; 80<\/td><\/tr><tr><td><strong>m3\/h\/reactor<\/strong><\/td><td>10 &#8211; 1.500<\/td><td>10-3.500\/100-100.000\/10-3.500<\/td><td>10 &#8211; 1.500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-clearfloat mod_clearfloat\"><\/div>\n\n\n\n<p class=\"has-small-font-size\">NOTE: The treatment capacity depends on the pollutant load to be removed per m3 and the final electrical load applied. Ah\/m3.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\">\n<a class=\"wp-block-ewatts-blocks-boton com_bt transparente normal flotar_1\" href=\"https:\/\/ewatts-tech.com\/en\/contact\/\">+ INFO<\/a>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-desplegable-in item\"><div class=\"pregunta com_titular_3\"><span class=\"icon-plus\"><\/span><p>Solutions and applications<\/p><\/div><div class=\"resposta\">\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">High non-biodegradable and \/ or toxic organic loads: (e-EOTph)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied directly or before applying biological treatment.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Improvement of effluent biodegradability: (e-EOTph \/ e-EOT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied directly or before applying biological treatment of effluent.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Removal of biologically persistent pollutants: (e-EOTph)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied directly in water before discharge to remove biorefractory compounds.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Lack of space and extension of biological treatment: (e-ECT \/ e-EOTph)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied before biological treatment to reduce load and residence time.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Too many soluble salts in the final effluent: (e-ECT \/ e-ERT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Substitutes chemical treatments for electrochemical systems + reverse osmosis (RO), or applied before discharge.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Presence of metals and low emission limits: (e-ECT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Highly effective on any type of heavy metal.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">External management of excessive aqueous waste: (e-EOTph)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Liquid waste is treated prior to on-site general treatment.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">External management of excessive sludge: (e-ECT \/ e-EOTph)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Substitutes physical-chemical treatment for EC and \/ or biological treatment for EOTph.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Water recovery: (e-ECT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Substitutes physical-chemical treatment for e-ECT.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Decontamination of contaminated groundwater: (e-FRR)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied directly on groundwater. Short duration on-site treatment.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Regeneration of scrubbing water: (e-SCR)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Applied to regenerate the scrubbing solution in-situ.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Expensive and hazardous disinfectants: (e-DSR)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">On-site generation of disinfectant.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Recovery of valuable metals: (e-EDT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Valuable metals are recovered from the effluent by electrodeposition.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Improved performance in biodigesters \/ deammonification: (e-NHR)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">Ammonium is constantly removed from the interior of the digester without reducing the digestible organic matter, cogenerating hydrogen and increasing methane production by 30%-50%.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h5 class=\"is-style-com_titular_6 wp-block-heading\">Hydrogen production and\/or cogeneration: (e-HHT)<\/h5>\n\n\n\n<p class=\"is-style-mas-junto\">A special EOT\/ERT reactor is used for the production of pure hydrogen or in certain wastewater\/liquid waste treatments co-generating hydrogen at the same time.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-desplegable-in item\"><div class=\"pregunta com_titular_3\"><span class=\"icon-plus\"><\/span><p>Benefits<\/p><\/div><div class=\"resposta\">\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Benefits of the technology&nbsp;(R = Reduction \/ Recovery)<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>No sludge produced (e-EOT) \/ 0% or much less (e-ECT) \/ &lt;30%-75% than other technologies.<strong> (R)<\/strong><\/li><li>Possible effluent recovery. <strong>(R)<\/strong><\/li><li>The sludge produced (e-ECT) is inert and easily dewatered.<\/li><li>Multiple treatment of pollutants.<\/li><li>Treatment of non-biodegradable, refractory or toxic water.<\/li><li>Treatment of water with high salinity, organic and nitrogenous load.<\/li><li>The process itself allows purification and disinfection.<\/li><li>Eliminates colour and odour.<\/li><li>Eliminates heavy metals.<\/li><\/ul>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Benefits of the process&nbsp;(S = Sustainable)<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Low operating costs and proportional to the load.<\/li><li>No reagents required. <strong>(S).<\/strong><\/li><li>Produces the<sup> <\/sup>least&nbsp;CO2 <strong>(S).<\/strong><\/li><li>Fast (instantaneous or max. 1h), optional online treatment.<\/li><li>Automated and remote controlled.<\/li><li>Low maintenance. Self-cleaning reactors.<\/li><\/ul>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Structural benefits<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>No civil works required.<\/li><li>Minimal footprint.<\/li><li>Optional modules and easy expansion.<\/li><li>Optional transfer of the treatment system. \u00b7 Mobile and compact plants.<\/li><li>Optional on-site treatment.<\/li><\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-desplegable-in item\"><div class=\"pregunta com_titular_3\"><span class=\"icon-plus\"><\/span><p>Other technologies and treatments<\/p><\/div><div class=\"resposta\">\n<h2 class=\"is-style-com_titular_6 wp-block-heading\" id=\"w-met\">Membrane treatments: (w-MET)<\/h2>\n\n\n\n<p>Microfiltration, Ultrafiltration, Reverse Osmosis, EDR.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Biological Treatments: (w-BIT)<\/h2>\n\n\n\n<p>SBR, MBR, Anaerobic digesters. UASB.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">UV radiation treatments: (w-UVT)<\/h2>\n\n\n\n<p>Low and medium pressure.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\" id=\"w-evt\">Evaporation Crystallization Treatments: (w-EVT)<\/h2>\n\n\n\n<p>1 to 4 effects. low temperature \/ vacuum evaporators.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Sludge Dewatering Treatments: (w-DET)<\/h2>\n\n\n\n<p>Filter presses. centrifuges. thermal drying.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n\n\n\n<h2 class=\"is-style-com_titular_6 wp-block-heading\">Incineration \/ Calcination Treatments: (w-ICT)<\/h2>\n\n\n\n<p>Incinerators \/ Calcinators for non-toxic waste.<\/p>\n\n\n\n<div class=\"wp-block-ewatts-blocks-botones mod_botons clearfix\"><\/div>\n<\/div><\/div>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-business mod_slider var_bg_gris\"><div class=\"maq_marges_verticals  maq_marges_horitzontals\"><div class=\"maq_contenidor_estret\"><h2 class=\"com_titular_1 \">Business cases<\/h2><div class=\"slider js_slick\">\n<div class=\"wp-block-ewatts-blocks-business-in slide\"><div class=\"maq_columnas cols_2 call_to_action_1\"><div class=\"maq_col foto\"><img decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/BC_ewatts_quimica_1920px.jpg\"\/><\/div><div class=\"maq_col centrar-verticalment\"><div class=\"com_destacat centrat-verticalment\"><h2 class=\"com_titular_2 \">Chemical Industry<\/h2><p><\/p><p class=\"call_to_action\"><a class=\"com_bt transparente normal\" href=\"https:\/\/ewatts-tech.com\/en\/business-cases\/#chemical-industry\">SEE +<\/a><\/p><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-business-in slide\"><div class=\"maq_columnas cols_2 call_to_action_1\"><div class=\"maq_col foto\"><img decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/BC_ewatts_farmaceutico_1920px.jpg\"\/><\/div><div class=\"maq_col centrar-verticalment\"><div class=\"com_destacat centrat-verticalment\"><h2 class=\"com_titular_2 \">Pharmaceutical Industry<\/h2><p><\/p><p class=\"call_to_action\"><a class=\"com_bt transparente normal\" href=\"https:\/\/ewatts-tech.com\/en\/business-cases\/#pharmaceutical-industry\">SEE +<\/a><\/p><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-business-in slide\"><div class=\"maq_columnas cols_2 call_to_action_1\"><div class=\"maq_col foto\"><img decoding=\"async\" src=\"https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/BC_ewatts_automocion_1920px.jpg\"\/><\/div><div class=\"maq_col centrar-verticalment\"><div class=\"com_destacat centrat-verticalment\"><h2 class=\"com_titular_2 \">Automotive Industry<\/h2><p><\/p><p class=\"call_to_action\"><a class=\"com_bt transparente normal\" href=\"https:\/\/ewatts-tech.com\/en\/business-cases\/#automotive-industry\">SEE +<\/a><\/p><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><\/div>\n\n\n\n\n\n<div class=\"wp-block-ewatts-blocks-landing mod_landing\"><div class=\"maq_columnas cols_2\">\n<div class=\"wp-block-ewatts-blocks-landing-in maq_col\"><a href=\"https:\/\/ewatts-tech.com\/en\/regeneration-recovery-and-recycling-by-electrochemical-means-e-r\/\"><div class=\"inner\"><h2 class=\"com_titular_2 ombra_text_fosca \"><strong>Regeneration, Recovery and Recycling<\/strong><\/h2><\/div><div class=\"img\" style=\"background-image:url(https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Slider_Tratamientio-Aguas_Ewatts_1920px_02.jpg)\"><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-ewatts-blocks-landing-in maq_col\"><a href=\"https:\/\/ewatts-tech.com\/en\/hydrogen-energy-and-electrochemical-cogeneration-e-h\/\"><div class=\"inner\"><h2 class=\"com_titular_2 ombra_text_fosca \">Hydrogen, Energy and Electrochemical Cogeneration<\/h2><\/div><div class=\"img\" style=\"background-image:url(https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/Producto_Hidrogeno_Cogeneracion_1920px.jpg)\"><\/div><\/a><\/div>\n<\/div><\/div>\n\n\n\n\n\n<div class=\"wp-block-ewatts-blocks-franja mod_ban ombra_text_fosca preview_call_to_action_1 contingut_enmig com_blanc\" style=\"background-image:url('https:\/\/ewatts-tech.com\/wp-content\/uploads\/2021\/03\/aigua2.jpg')\"><div class=\"inner maq_marges_horitzontals\"><div class=\"maq_contenidor\"><div class=\"bloc_contingut\"><h2 class=\"com_titular_1\">Contact us<\/h2><div class=\"text\"><p>If you are interested or would like more information about our products and services, please feel free to contact us.<\/p><\/div><p class=\"call_to_action\"><a class=\"com_bt semiblanc normal\" href=\"https:\/\/ewatts-tech.com\/en\/contact\/\">CONTACT US<\/a><\/p><\/div><\/div><\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-987","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/pages\/987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/comments?post=987"}],"version-history":[{"count":6,"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/pages\/987\/revisions"}],"predecessor-version":[{"id":1270,"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/pages\/987\/revisions\/1270"}],"wp:attachment":[{"href":"https:\/\/ewatts-tech.com\/en\/wp-json\/wp\/v2\/media?parent=987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}